LIFEPAK® 1000 Getting Started

Getting Started

Thank you for purchasing the LIFEPAK 1000 defibrillator. You have joined lifesaving teams around the world who are committed to meeting their diverse defibrillation needs. This guide provides the information you need to get started.

Please complete these five easy steps to get started.

1. Check the contents of the LIFEPAK 1000 defibrillator box

  1. Carefully remove the defibrillator from the boxes you receive.
  2. Check the contents of each box to be sure everything listed on the packlist is included.
  3. Examine the outside of the defibrillator, battery pak, and any accessories for signs of damage that may have occurred during shipping.
  4. If possible, save the shipping boxes and inserts in case you need to ship the defibrillator in the future.

2. Install the LIFEPAK 1000 battery pak in the defibrillator

The LIFEPAK 1000 defibrillator can be powered by two types of batteries:
- a nonrechargeable Lithium manganese dioxide battery
- a rechargeable Lithium-ion batter

For rechargeable batteries only: You must fully charge the battery before first use. Insert the battery into the battery charger and verify that the green LED flashes to indicate that the battery is charging. Continue charging the battery until the LED changes to steady green. Only the LIFEPAK 1000 Defibrillator Battery Charger can be used to charge the battery.
For both battery types: Check the charge level before installing the battery in the defibrillator. Press the button on the battery and check the fuel gauge (row of green lights above the battery button). You should see four green lights illuminated.

Note: Always carry a spare, fully-charged battery.

To install the battery:

  1. Hold the battery so that the label faces away from you, and then insert the connector end of the battery into the battery compartment.
  2. Slide the battery pak all the way in until it latches securely. The defibrillator turns on and then off automatically and updates the readiness display.
  3. Verify that the OK symbol and the battery status symbols are visible in the readiness display.

3. Install the therapy electrodes in the defibrillator

QUIK-COMBO® pacing/defibrillation/ECG electrodes with the REDI-PAK™ preconnect system are provided. These electrodes are designed for preconnection to the defibrillator.

  1. Insert the electrode connector as shown in the following illustration:
  2. Slide the electrode packet into the inner sleeve of the carrying case lid.

                              mceclip2.png

 

4. Familiarize yourself with the defibrillator and accessories

Do not remove the defibrillator from its case.

A printed copy of the LIFEPAK 1000 Defibrillator Operating Instructions is included.

For more information, see www.physio-control.com.

5. Customize the defibrillator operating settings if needed

As determined by your medical director, some of the operating settings can be changed to match your emergency medical system protocol.

 

mceclip3.png